HVAC Systems

When your business is operating an animal care facility, sanitizing the air isn’t a luxury; it’s mandatory. Your HVAC system or furnace is a vital component in the strategy to contain and limit the spread of air borne infections.

When an infected animal coughs, sneezes or sheds dander, they release pathogens into the air via droplets. These infected droplets evaporate into millions of tiny particles which circulate through the air. They literally cling to dust and can remain infectious until inhaled by another animal or person. Once present, these airborne pathogens can circulate throughout your HVAC system and remain infectious for up to two weeks.

Air flow through HVAC system diagram

With our multiple air and coil surface disinfection units, PetAirapy can properly size your new or existing HVAC system to quickly and efficiently kill over 99.9% of these pathogens. Our powerful UVC light technology eliminates and kills allergens, bacteria and viruses such as Kennel Cough, Canine Influenza and all flu viruses, as well as other illnesses before they have a chance to spread infection.

PAH-N08 & PAH-N12

PA-160 and 260 HVAC UV systems

Power : AC 120V~277V Compatible
Wiring : Plug in
Switch : On/Off Standard
Size : 12.5″ (14.5″) L x 7.3” W x 2.5” D
Safety: Integrated viewport
Lamp Hours : 9,000 (1 year for 24/7 operation)
Ozone : None
Warranty : 5 years for unit, 1 year for UV-C lamp

Description :
PAH-N08 and PAH-N12 are engineered and manufactured to fit into any new and existing HVAC (Indoor Split System). Constant exposure of UV-C germicidal energy within HVAC system will disinfect pathogens such as bacteria, virus and mold at 99.9%.

Each unit is constructed with stainless steel and aluminum for lasting and sturdy structure. View port and safety switch are integrated for safety inspection. UV-C lamp has no more than 4.5mg mercury content in the lamp and produce no ozone.

Ideal location of installation is above the evaporator coil inside of HVAC system to achieve maximum disinfection of pathogens both in air stream and surface of the evaporator coil. Unit needs to be kept on 24/7 for optimum and continuous disinfection.

To learn more about the PAH series or to place an order:
contact us today

Power : AC 120V~277V Compatible
Wiring : Plug in
Switch : On/Off Standard
Irradiation : 360 degree
Timer : Delayed start timer and disinfection timer
Size : 10”L x 10”W x 22”D
Lamp Hours : 9,000 (1year for 24/7 operation)
Ozone : None
Warranty : 5 years for unit, 1 year for UV-C lamp

Description :
PED-460 is engineered and manufactured to be portable and used for surface and air disinfection of unoccupied rooms such as surgical rooms. This unit has integrated timer to set up the unit before irradiation and operate unoccupied room. Strong UVC germicidal energy will disinfect pathogens such as bacteria, virus and mold effectively on the surface and in the air stream as well.

Each unit is constructed with stainless steel and aluminum for lasting and sturdy structure. UV-C lamp has no more than 4.5mg mercury content in the lamp and produce no ozone.

To learn more about the PED-460 or to place an order:
contact us today

PPR-N08, N12, N20 & N40

Power : AC 120V~277V Compatible
Wiring : Direct Wiring
Size : 21”L x 3.3”W x 2.7”D
Safety : Viewport and safety switch (included)
Lamp Hours : 9,000 (1 year for 24/7 operation)
Ozone : None
Warranty : 5 years for unit, 1 year for UV-C lamp

Description :
PPR-N08, PPR-N12, PPR-N20 and PPR-N40 are engineered and manufactured to fit into any new and existing HVAC (Packaged System). Constant exposure of UV-C germicidal energy within HVAC system will disinfect pathogens such as bacteria, virus and mold at 99.9%.

Each unit is constructed with stainless steel and aluminum for lasting and sturdy structure. Viewport and safety switch are included. UV-C lamp has no more than 4.5mg mercury content in the lamp and produce no ozone.

Ideal location of installation is between evaporator coil and plenum on supply air side within HVAC system to achieve maximum disinfection of pathogens both in air stream and surface of the evaporator coil. And unit needs to be kept on 24/7 for optimum and continuous disinfection.

To learn more about the PPR series or to place an order:
contact us today

PPR series HVAC for animal businesses

PPR-160, 260, 360, 460

PPR series HVAC for animal businesses

Power : AC 120V~277V Compatible
Wiring : Direct Wiring
Size : 21”L x 3.3”W x 2.7”D
Safety : Viewport and safety switch (included)
Lamp Hours : 9,000 (1 year for 24/7 operation)
Ozone : None
Warranty : 5 years for unit, 1 year for UV-C lamp

Description :
PPR-160, PPR-260, PPR-360 & PPR-460 are engineered and manufactured to fit into any new and existing HVAC (Packaged System). Constant exposure of UV-C germicidal energy within HVAC system will disinfect pathogens such as bacteria, virus and mold at 99.9%.

Each unit is constructed with stainless steel and aluminum for lasting and sturdy structure. Viewport and safety switch are included. UV-C lamp has no more than 4.5mg mercury content in the lamp and produce no ozone.

Ideal location of installation is between evaporator coil and plenum on supply air side within HVAC system to achieve maximum disinfection of pathogens both in air stream and surface of the evaporator coil. And unit needs to be kept on 24/7 for optimum and continuous disinfection.

To learn more about the PPR series or to place an order: